Skip to product information

CAN FD ETH RS232/RS485 Converter Waveshare 32600

CAN FD ETH RS232/RS485 Converter Waveshare 32600

Regular price 6 098₴
Regular price Sale price 6 098₴

SKU: 1085

In stock

Description

CAN FD Protocol Converter is a bi-directional CAN FD to ETH/RS232/RS485 converter, supporting 5 data conversion modes and CAN 2.0A/2.0B protocols, as well as heartbeat and registration packet functions.

Key Features

CAN FD ETH RS232/RS485 Converter is a DIN-rail mountable CAN FD to Ethernet/RS232/RS485 converter with high speed, low latency, and stable operation. It supports five data conversion modes: transparent conversion, transparent conversion with ID, standard protocol conversion, Modbus protocol conversion, and custom protocol conversion. It enables interaction between CAN devices and network/serial ports, compatible with CAN FD and CAN 2.0A/2.0B protocols.

Industrial-grade design, stable operation at -40°C ~ 85°C, wide power supply range of 9V ~ 36V, CAN FD baud rates in arbitration domain 5Kbps~1Mbps and in data domain 100Kbps~5Mbps.

Supports parameter configuration via host computer, built-in 120Ω termination resistors (switchable via DIP switches), supports DIN rail mounting, easy to configure and install.

Specifications

Category Parameter Description
Basic Parameters Operating Voltage DC 9V ~ 36V
Dimensions 110 × 27 × 85.6 (mm)
Mounting Method DIN Rail Mount
Reset Button Long press to restore factory settings
Indicator Lights POWER, WORK, COM and CAN
Interface Parameters CAN Port Specification 1-channel CAN port, supports CAN FD, compatible with CAN 2.0A/2.0B
CAN Baudrate Arbitration Domain: 5Kbps ~ 1Mbps
Data Domain: 100Kbps ~ 5Mbps
Termination Resistor Built-in 2 × 120Ω termination resistors.
Switching one DIP switch to ON connects one 120Ω resistor in parallel.
Switching both to ON connects two 120Ω resistors in parallel
Network Port Specification RJ45, 10/100Mbps, adaptive cross-over
Serial Port Specification Supports 1-channel RS485 or RS232
Operating Environment Operating Temperature -40℃ ~ 85℃
Storage Temperature -40℃ ~ 105℃
Operating Humidity 5% ~ 95% RH (non-condensing)
Storage Humidity 5% ~ 95% RH (non-condensing)
Software Functions Network Protocol TCP server, TCP client, UDP server, UDP client (network port only)
Modbus Gateway Network port: CAN FD to Modbus TCP (Master/Slave)
Serial port: CAN FD to Modbus RTU (Master/Slave)
Transmit Messages Supports up to 64 transmit messages
Receive Messages Supports up to 64 receive messages
Protocol Conversion Transparent conversion, transparent conversion with ID, standard conversion, Modbus conversion, custom conversion
CAN ID Supports standard frames and extended frames
Frame ID Filtering Supports only standard frames, only extended frames, and custom frame ID input (up to 32 groups)
Frame Packaging Time Supports setting the number of frames and frame packaging time (network port)
Direction Change Supports bi-directional conversion, serial/Ethernet port to CAN only, and CAN to serial/Ethernet port only
Firmware Upgrade Supports firmware upgrade via host computer
Parameter Configuration AT commands and host computer software configuration
Other Functions Supports heartbeat packets; registration packets; normal, loopback, and listen-only modes (network port)
Protection Parameters ESD Protection Air discharge: 8 KV, Contact discharge: 6 KV
EFT/Burst Power circuit: 2KV; RS485/RS232: 1KV; Network port & CAN port: 1KV
Surge Immunity Test Power circuit: 1KV differential mode, 2KV common mode;
CAN circuit: 2KV common mode;
Serial port & Network port: 2KV common mode

Core Functionality

Supports bi-directional data transmission of CAN FD to ETH/RS232/RS485

CAN FD ETH RS232/RS485 Converter, core functionality

Arbitration Domain Baud Rate

CAN FD arbitration domain baud rate: 5Kbps ~ 1Mbps

CAN FD ETH RS232/RS485 Converter, arbitration domain baud rate

Data Domain Baud Rate

CAN FD data domain baud rate: 100Kbps ~ 5Mbps

CAN FD ETH RS232/RS485 Converter, data domain baud rate

Industrial Grade Design

CAN FD ETH RS232/RS485 Converter, industrial grade design

Supports Multiple Conversion Modes

Transparent conversion, transparent conversion with ID, standard conversion, Modbus protocol conversion, and custom conversion with custom headers and trailers

CAN FD ETH RS232/RS485 Converter, supports multiple conversion modes

Transparent Conversion

Achieves original conversion between CAN FD frames and serial/Ethernet frames

CAN FD ETH RS232/RS485 Converter, transparent conversion

Transparent Conversion with ID

Transmits ID information from serial/Ethernet frames to CAN FD frames

CAN FD ETH RS232/RS485 Converter, transparent conversion with ID

Standard Conversion

Conversion between 13-byte standard CAN frame format and 69-byte standard CAN FD frame format

CAN FD ETH RS232/RS485 Converter, standard conversion

Modbus Protocol Conversion

Implements Modbus data transmission over CAN bus through packet segmentation and reassembly

CAN FD ETH RS232/RS485 Converter, Modbus protocol conversion

Custom Protocol Conversion

Users can customize frame headers and trailers to achieve bi-directional data conversion

CAN FD ETH RS232/RS485 Converter, custom protocol conversion

3 Frame Filtering Methods, 32 Sets of Configurable Filters

Supports receiving only extended frames, receiving only standard frames, and custom frame ID reception. In custom mode, users can configure up to 32 sets of filtering methods to avoid large volumes of data interference

CAN FD ETH RS232/RS485 Converter, 3 frame filtering methods

Parameter Configuration via Host Computer

CAN FD ETH RS232/RS485 Converter, parameter configuration

Function Overview

Heartbeat Packet Function *

CAN Heartbeat Packet: Acts as a fixed query command, sending heartbeat packets over the CAN network.
Network Heartbeat Packet: Informs the server that the device is active and maintains a stable network connection with the server.

CAN FD ETH RS232/RS485 Converter, heartbeat packet function

* when using the Ethernet port and CAN as data transmission channels

Registration Packet Function *

Allows the server to identify the source device of incoming data, or serves as an authentication key for the device to access authorized server functions.

CAN FD ETH RS232/RS485 Converter, registration packet function

* when using the Ethernet port and CAN as data transmission channels

Application Scenarios

CAN FD ETH RS232/RS485 Converter, BMS battery monitoring

BMS Battery Monitoring

CAN FD ETH RS232/RS485 Converter, industrial automation

Industrial Automation

CAN FD ETH RS232/RS485 Converter, EV charging

EV Charging

CAN FD ETH RS232/RS485 Converter, traffic monitoring

Traffic Monitoring

Interface Description

CAN FD ETH RS232/RS485 Converter, interface description

Outline Dimensions

CAN FD ETH RS232/RS485 Converter, outline dimensions

CAN FD Converter Selection

Model CAN FD TO ETH CAN FD TO RS232/RS485 CAN FD ETH RS232/RS485 Converter
Product Type CAN FD to ETH CAN FD to RS485/RS232 CAN FD to ETH/RS485/RS232
CAN FD Supported
EMC Protection Level 3 Level 3 Level 3, full power/interface/communication isolation
Exterior Design
Part number: EV
View full details

Description

CAN FD Protocol Converter is a bi-directional CAN FD to ETH/RS232/RS485 converter, supporting 5 data conversion modes and CAN 2.0A/2.0B protocols, as well as heartbeat and registration packet functions.

Key Features

CAN FD ETH RS232/RS485 Converter is a DIN-rail mountable CAN FD to Ethernet/RS232/RS485 converter with high speed, low latency, and stable operation. It supports five data conversion modes: transparent conversion, transparent conversion with ID, standard protocol conversion, Modbus protocol conversion, and custom protocol conversion. It enables interaction between CAN devices and network/serial ports, compatible with CAN FD and CAN 2.0A/2.0B protocols.

Industrial-grade design, stable operation at -40°C ~ 85°C, wide power supply range of 9V ~ 36V, CAN FD baud rates in arbitration domain 5Kbps~1Mbps and in data domain 100Kbps~5Mbps.

Supports parameter configuration via host computer, built-in 120Ω termination resistors (switchable via DIP switches), supports DIN rail mounting, easy to configure and install.

Specifications

Category Parameter Description
Basic Parameters Operating Voltage DC 9V ~ 36V
Dimensions 110 × 27 × 85.6 (mm)
Mounting Method DIN Rail Mount
Reset Button Long press to restore factory settings
Indicator Lights POWER, WORK, COM and CAN
Interface Parameters CAN Port Specification 1-channel CAN port, supports CAN FD, compatible with CAN 2.0A/2.0B
CAN Baudrate Arbitration Domain: 5Kbps ~ 1Mbps
Data Domain: 100Kbps ~ 5Mbps
Termination Resistor Built-in 2 × 120Ω termination resistors.
Switching one DIP switch to ON connects one 120Ω resistor in parallel.
Switching both to ON connects two 120Ω resistors in parallel
Network Port Specification RJ45, 10/100Mbps, adaptive cross-over
Serial Port Specification Supports 1-channel RS485 or RS232
Operating Environment Operating Temperature -40℃ ~ 85℃
Storage Temperature -40℃ ~ 105℃
Operating Humidity 5% ~ 95% RH (non-condensing)
Storage Humidity 5% ~ 95% RH (non-condensing)
Software Functions Network Protocol TCP server, TCP client, UDP server, UDP client (network port only)
Modbus Gateway Network port: CAN FD to Modbus TCP (Master/Slave)
Serial port: CAN FD to Modbus RTU (Master/Slave)
Transmit Messages Supports up to 64 transmit messages
Receive Messages Supports up to 64 receive messages
Protocol Conversion Transparent conversion, transparent conversion with ID, standard conversion, Modbus conversion, custom conversion
CAN ID Supports standard frames and extended frames
Frame ID Filtering Supports only standard frames, only extended frames, and custom frame ID input (up to 32 groups)
Frame Packaging Time Supports setting the number of frames and frame packaging time (network port)
Direction Change Supports bi-directional conversion, serial/Ethernet port to CAN only, and CAN to serial/Ethernet port only
Firmware Upgrade Supports firmware upgrade via host computer
Parameter Configuration AT commands and host computer software configuration
Other Functions Supports heartbeat packets; registration packets; normal, loopback, and listen-only modes (network port)
Protection Parameters ESD Protection Air discharge: 8 KV, Contact discharge: 6 KV
EFT/Burst Power circuit: 2KV; RS485/RS232: 1KV; Network port & CAN port: 1KV
Surge Immunity Test Power circuit: 1KV differential mode, 2KV common mode;
CAN circuit: 2KV common mode;
Serial port & Network port: 2KV common mode

Core Functionality

Supports bi-directional data transmission of CAN FD to ETH/RS232/RS485

CAN FD ETH RS232/RS485 Converter, core functionality

Arbitration Domain Baud Rate

CAN FD arbitration domain baud rate: 5Kbps ~ 1Mbps

CAN FD ETH RS232/RS485 Converter, arbitration domain baud rate

Data Domain Baud Rate

CAN FD data domain baud rate: 100Kbps ~ 5Mbps

CAN FD ETH RS232/RS485 Converter, data domain baud rate

Industrial Grade Design

CAN FD ETH RS232/RS485 Converter, industrial grade design

Supports Multiple Conversion Modes

Transparent conversion, transparent conversion with ID, standard conversion, Modbus protocol conversion, and custom conversion with custom headers and trailers

CAN FD ETH RS232/RS485 Converter, supports multiple conversion modes

Transparent Conversion

Achieves original conversion between CAN FD frames and serial/Ethernet frames

CAN FD ETH RS232/RS485 Converter, transparent conversion

Transparent Conversion with ID

Transmits ID information from serial/Ethernet frames to CAN FD frames

CAN FD ETH RS232/RS485 Converter, transparent conversion with ID

Standard Conversion

Conversion between 13-byte standard CAN frame format and 69-byte standard CAN FD frame format

CAN FD ETH RS232/RS485 Converter, standard conversion

Modbus Protocol Conversion

Implements Modbus data transmission over CAN bus through packet segmentation and reassembly

CAN FD ETH RS232/RS485 Converter, Modbus protocol conversion

Custom Protocol Conversion

Users can customize frame headers and trailers to achieve bi-directional data conversion

CAN FD ETH RS232/RS485 Converter, custom protocol conversion

3 Frame Filtering Methods, 32 Sets of Configurable Filters

Supports receiving only extended frames, receiving only standard frames, and custom frame ID reception. In custom mode, users can configure up to 32 sets of filtering methods to avoid large volumes of data interference

CAN FD ETH RS232/RS485 Converter, 3 frame filtering methods

Parameter Configuration via Host Computer

CAN FD ETH RS232/RS485 Converter, parameter configuration

Function Overview

Heartbeat Packet Function *

CAN Heartbeat Packet: Acts as a fixed query command, sending heartbeat packets over the CAN network.
Network Heartbeat Packet: Informs the server that the device is active and maintains a stable network connection with the server.

CAN FD ETH RS232/RS485 Converter, heartbeat packet function

* when using the Ethernet port and CAN as data transmission channels

Registration Packet Function *

Allows the server to identify the source device of incoming data, or serves as an authentication key for the device to access authorized server functions.

CAN FD ETH RS232/RS485 Converter, registration packet function

* when using the Ethernet port and CAN as data transmission channels

Application Scenarios

CAN FD ETH RS232/RS485 Converter, BMS battery monitoring

BMS Battery Monitoring

CAN FD ETH RS232/RS485 Converter, industrial automation

Industrial Automation

CAN FD ETH RS232/RS485 Converter, EV charging

EV Charging

CAN FD ETH RS232/RS485 Converter, traffic monitoring

Traffic Monitoring

Interface Description

CAN FD ETH RS232/RS485 Converter, interface description

Outline Dimensions

CAN FD ETH RS232/RS485 Converter, outline dimensions

CAN FD Converter Selection

Model CAN FD TO ETH CAN FD TO RS232/RS485 CAN FD ETH RS232/RS485 Converter
Product Type CAN FD to ETH CAN FD to RS485/RS232 CAN FD to ETH/RS485/RS232
CAN FD Supported
EMC Protection Level 3 Level 3 Level 3, full power/interface/communication isolation
Exterior Design
Part number: EV
Regular price 6 098₴
Regular price Sale price 6 098₴

In stock